Resultado da pesquisa (2)

Termo utilizado na pesquisa Doppler ultrasound

#1 - B-mode and Doppler ultrasound of bitches’ kidneys with mammary neoplasia submitted to adjuvant chemotherapy

Abstract in English:

Mammary neoplasia represents the most frequently diagnosed type of neoplasia in bitches. Although surgical removal is the procedure of choice for therapeutic management, chemotherapy protocols appear as important allies and adjuvants. Despite the great advances that have occurred in the field of cancer therapy, the systemic repercussions of these drugs still impose important limitations on their use. In this sense, the development of increasingly targeted therapeutic protocols and preventive monitoring of patients represent important strategies to avoid possible complications – among them, Acute Kidney Injury (AKI). Routinely, ultrasound evaluation is used to identify morphological or metastatic variations in abdominal cavity organs. Acting complementary to the B-mode evaluation, Doppler mapping proves to be efficient in recognizing alterations in vascular hemodynamics. Therefore, the objective of the present study was to evaluate the use of B-mode and Doppler ultrasound to identify renal morphological and hemodynamic alterations in bitches with mammary neoplasia submitted to adjuvant chemotherapy protocols that associate gemcitabine with carboplatin. Thirteen bitches were included, without distinction of breed and between seven and 13 years of age. The animals were evaluated ultrasonographically at two different times during three consecutive chemotherapy cycles: before (T0) and one and a half hours after each cycle (T1), for 42 days. No morphological changes were observed in B-mode throughout the chemotherapy protocol. However, the Doppler velocimetry indices demonstrated statistical differences before (T0) and after (T1) the administration of the drugs. It was concluded that Doppler ultrasound could be used as a complementary method for monitoring the renal response of patients exposed to nephrotoxic drugs and potentially causing renal injury.

Abstract in Portuguese:

As neoplasias mamárias representam o tipo de neoplasma mais frequentemente diagnosticado em fêmeas da espécie canina. Embora a remoção cirúrgica seja o procedimento de eleição para a conduta terapêutica, os protocolos quimioterápicos aparecem como importantes aliados e adjuvantes. Apesar dos grandes avanços ocorridos na área da terapia oncológica, as repercussões sistêmicas destes fármacos ainda impõem importantes limitações ao seu uso. Neste sentido, o desenvolvimento de protocolos terapêuticos cada vez mais direcionados e o monitoramento preventivo dos pacientes representam estratégias importantes para evitar possíveis complicações - dentre elas, a injúria renal aguda (IRA). Rotineiramente, a avaliação ultrassonográfica é utilizada para identificação de variações morfológicas ou metastáticas em órgãos da cavidade abdominal. Atuando de forma complementar à avaliação em modo-B, o mapeamento Doppler mostra-se eficiente no reconhecimento de alterações na hemodinâmica vascular. Portanto, o objetivo do presente estudo foi avaliar a utilização da ultrassonografia modo-B e Doppler como método para identificação de alterações morfológicas e hemodinâmicas renais em cadelas com neoplasias mamárias submetidas a protocolos quimioterápicos adjuvantes que associam a gencitabina à carboplatina. Foram incluídas 13 fêmeas caninas, sem distinção quanto a raça e com idades entre sete e 13 anos. Os animais foram avaliados ultrassonograficamente em dois momentos distintos durante três ciclos quimioterápicos consecutivos: antes (T0) e uma hora e meia após a realização de cada ciclo (T1), totalizando 42 dias. Não foram observadas alterações morfológicas em modo-B ao longo do protocolo quimioterápico. Entretanto, os índices dopplervelocimétricos demonstraram diferenças estatísticas antes (T0) e após (T1) a administração dos fármacos. Concluiu-se que a ultrassonografia Doppler pode ser utilizada como método complementar para o monitoramento da resposta renal de pacientes expostos a fármacos nefrotóxicos e potencialmente causadores de injúrias renais.


#2 - Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

Abstract in English:

B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.

Abstract in Portuguese:

O exame ultrassonográfico modo-B é uma importante ferramenta diagnóstica que permite caracterizar a anatomia interna dos órgãos e, complementada pelo exame modo Doppler, possibilita realizar a avaliação hemodinâmica vascular, aumentando a acurácia diagnóstica. Desta forma, este trabalho teve como objetivo a caracterização ultrassonográfica e mensuração dos segmentos do bulbo ocular modo-B, assim como a avaliação da artéria oftálmica externa pelo Doppler colorido e pulsado. Foram avaliados 60 bulbos oculares de 30 cães de diferentes raças utilizando transdutor microconvexo de 8,5MHz. Inicialmente foi realizada biometria por meio do exame em modo-B dos seguintes seguimentos: comprimento axial (M1), profundidade da câmara anterior (M2), espessura da lente (M3), comprimento da lente (M4), profundidade da câmara vítrea (M5), comprimento do disco óptico (M6) e diâmetro do nervo óptico (M7). A artéria oftálmica externa foi identificada pelo Doppler colorido e seu fluxo foi avaliado por meio do Doppler pulsado, sendo mensurados: velocidade do pico sistólico (VPS), velocidade diastólica final (VDF), índice de resistividade (IR) e índice de pulsatilidade (IP). Não foi verificada diferença estatística para os valores biométricos dos seguimentos oculares entre os olhos direito e esquerdo (p>0,05). A profundidade da câmera vítrea (M5), mostrou-se a variável biométrica com maior simetria bilateral, variando entre 0,79 a 0,87cm e 0,78 a 0,86cm para o olho direito e esquerdo, respectivamente. A artéria oftálmica foi visibilizada sobre o nervo óptico em direção ao bulbo ocular, com fluxo marcado em vermelho. Não houve diferença estatística significativa entre os valores Dopplervelocimétricos da artéria oftálmica entre do olho direito e esquerdo dos animais avaliados (p>0.05). O índice de resistividade (IR) médio evidenciou valores médios sendo igual a 0,63±0,03, bilateralmente. A velocidade basal média foi 17,50cm/s e 18,18cm/s no pico sistólico e 6,21cm/s e 6,68cm/s no final da diástole, para os olhos direito e esquerdo, respectivamente. A caracterização anatômica, biométrica e hemodinâmica utilizando o exame ultrassonográfico modo-B e as modalidades do Doppler permitiram a avaliação ultrassonográfica e Dopplervelocimétrica dos componentes do bulbo ocular nos cães de diferentes raças, podendo ser utilizados na rotina clínica oftalmológica para identificação de patologias oculares.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV